UG-5-AFR-230V-Z  - Calectro United Kingdom  Sales

BRAND Calectro
Product UG-5-AFR-230V-Z
Description air duct smoke switch
Internal code 1310867
Weight 1
Custom code 85311030
Technical specification 230 VAC DIBt The DIBt-approved Uniguard smoke detector is designed to detect smoke in ventilation ducts and combines a smoke detector with an adapter system, with a pipe and housing specifically for a Optimum airflow has been designed by the smoke detector. The UG-5 can be installed on either side of the channel in Four different positions can be installed: 0°, 90°, 180° and 270°. Patented Power supply: 230 V AC -15%, +10% Smoke detector type: UG-5-AFR-230V optical Max. power consumption: 30 mA Operating temperature: -10°C to +55°C Max. humidity: 99% RH Air speed range: 1 to 20 m/s Approvals: VdS G213014, CE, prEN-54-27, DIBt: Z-78.6-232 Smoke alarm unlocking via remote reset Relay output: Potential-free Smoke alarm relay: Two 250 V, 8A switch contacts Service alarm: One changeover contact 250 V, 5 A System fault alarm: One changeover contact 250 V, 5 A Air speed alarm alarm: One switch contact 250 V, 5 A LED on smoke detector: Green: service alarm (contamination) Red smoke alarm LED on circuit board: Green: normal operation Yellow - system error Yellow - air speed alert Adapter housing: ABS Protection class: IP54

Please Contact Us to Order to offer competitive prices and delivery time for Calectro - UG-5-AFR-230V-Z air duct smoke switch number, also you may ask some other model number is well. We can offer competitive price, and delivery time with wide products distribution network in United Kingdom Industrial products Market. 

WE SELL ONLY NEW AND ORIGINAL PRODUCTS!

Our company is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.

More products of Calectro

UG-5-AFR-24V-ST2

air duct smoke switch 24 V AC/DC

ST2

Venturi-Rohr Länge 600 mm für UG-5

UG-MB-75

console

UG-Cover-75

protective housing

ABAV-S3-230V

Steuergerät

CPS-A

Differential pressure transmitter -50 - +3500 Pa

UG-5-AFR-24V.

Complete unit including the alarm inside it

CPS-D-A

differential pressure transmitter

VR-0.6m

venturi tube

UG-3-A4-0

Air duct smoke detector 24 V AC/DC

CLA-24/230V

Leakage alarm for electrically conductive liquids

UG-3-A5-0

air duct smoke switch

STB-4 514010

Smoke detector base

PTH-3203

pressure differentrial

VDS CE24 V

Channel smoke detector

EVC-PY-DA-HS

Replacement smoke alarm UG-5

CLA-ST

Inherence sensor tape

UG-3-A40-VR06

Channel smoke switch

UG-3-0

air duct smoke switch

UG-3-A4O

detector